Ask for price

Class 1 Dual-Channel Noise Dosimeter

SV 102A+

The SV 102A+ Class 1 Dual-Channel Noise Dosimeter represents a groundbreaking advancement in occupational noise monitoring, specifically designed to meet the complex demands of the UK workplace environment. This Class 1 dual-channel noise dosimeter sets itself apart with its ability to perform detailed noise exposure assessments on both sides of the head, a feature crucial in environments where noise sources are directionally dominant or asymmetric.

In the UK, where diverse work settings range from bustling urban construction sites to precision-demanding military and aerospace sectors, the SV 102A+’s dual-channel technology offers an unparalleled advantage. By utilizing two microphones, the dosimeter can simultaneously measure noise exposure at both ears, providing a more accurate representation of the auditory challenges workers face.

MIRE Technology: Advancing Noise Measurement Standards

The SV 102A+ goes a step further with its MIRE (Microphone In Real Ear) technology, compliant with ISO 11904 standards. This innovative approach is crucial for settings where noise sources are near the ear, such as in call centers or under pilot helmets in military aircraft and tanks. MIRE technology is also instrumental in assessing the real-world effectiveness of hearing protection devices, making the SV 102A+ an essential tool for industries focused on auditory safety, including those adhering to stringent aerospace standards set by organizations like NASA and ESA.

In line with the UK’s Control of Noise at Work Regulations 2005, the SV 102A+ not only ensures compliance with legal requirements but also advances the standard of workplace noise monitoring. Its sophisticated features cater to the nuanced needs of UK industries, offering a robust solution for accurately assessing and managing noise exposure risks.

dual-Channel
Dual Channel
separator
class 1
Class 1
separator
bestseller
Bestseller

Main

Features

background

MIRE Measurement Technology for the UK Workplace

Microphone in Real Ear: Precise Noise Exposure Analysis

The SV 102A+ employs the innovative ISO 11904-1 MIRE (Microphone in Real Ear) measurement technique, a critical tool for accurate noise exposure assessment in specialized UK work environments. This advanced method involves capturing sound directly at the ear canal using the specialized SV 25S microphone probe. This approach is particularly effective in situations where traditional dosimetry is insufficient, such as in UK call centers where noise originates from headsets. By performing detailed one-third octave band analysis, the SV 102A+ provides a comprehensive and accurate assessment of noise exposure, ensuring compliance with UK workplace noise regulations. The integration of MIRE measurements necessitates the use of the SV 25S MIRE microphone along with 1/3 octave analysis capabilities.
mire microphone
background

Class 1 Precision for UK Noise Monitoring

Combining Noise Dosimeter and Sound Level Meter Capabilities

Adhering to the stringent standards of BS EN 61672-1, the SV 102A+ stands out as a highly precise noise monitoring solution suitable for the diverse requirements of UK workplaces. It functions both as a Class 1 noise dosimeter and a sound level meter, ensuring accuracy even under challenging conditions. This includes operating in extremely low temperatures (down to -10°C) and in environments where noise is predominantly high-frequency, in line with the recommendations of BS EN ISO 9612. The SV 102A+ operates at a high sampling rate of 48 kHz, guaranteeing precise and reliable noise level readings critical for maintaining UK workplace health and safety standards.
Class 1 Precision for UK Noise Monitoring
background

Dual-Channel Input for Comprehensive UK Noise Assessment

Class 1 Measurements with Dual Microphone Capability

The SV 102A+ is uniquely equipped with two input channels, allowing for the simultaneous use of two microphones. This dual-channel feature is pivotal for UK workplaces, as it facilitates the placement of microphones on both sides of a worker's head, ensuring a comprehensive assessment of noise exposure. In addition, by incorporating the MIRE microphone technology, the SV 102A+ can be configured with one microphone positioned on the shoulder and another inside the ear. This setup is particularly beneficial for assessing the effectiveness of hearing protectors or headsets, such as those used by military pilots, providing a detailed verification of attenuation in various noise-intensive environments across the UK.
Dual-Channel input

Main

Application

background

Occupational Noise Assessment in the UK

Class 1 Noise Measurements for Work Environments

The SV 102A+ emerges as a distinctive Class 1 dual-channel noise dosimeter, specifically engineered for precise noise exposure measurement in UK workplaces. This device is exceptionally suitable for environments where high-frequency noise prevails and in conditions as cold as below zero. Its compatibility with the MIRE (Microphone in Real Ear) measurement technique, adhering to ISO 11904-1 standards, enhances its application. The dual-channel capability of the SV 102A+ offers a comprehensive noise measurement solution, addressing the diverse and challenging acoustic scenarios encountered in various UK work settings.
Read more
mire microphone svantek

Ask for

SV 102A+ Class 1 Dual-Channel Noise Dosimeter

SV 102A+ Class 1 Dual-Channel Noise Dosimeter

The standard SV 102A+ kit includes SV15 preamplifier with cable, SV 7052E microphone, 2x AA batteries, 8 GB memory card and a USB cable for communication with PC. Each SV 102A+ has its factory calibration certificate and a 36-MONTH WARRANTY upon product registration. The standard kit also includes license for PC software.

See all accessories

SF102A+_3OCT - License of 1/1 & 1/3 octave analysis for SV 102A+

SF102A+_3OCT - License of 1/1 & 1/3 octave analysis for SV 102A+

License of 1/1 & 1/3 octave analysis for SV 102A+

SF102A+_REC - License of Audio events recording for SV 102A+

SF102A+_REC - License of Audio events recording for SV 102A+

License of Audio events recording for SV 102A+













    Products in the enquiry (1)

    I hereby consent to the processing of my personal data, i.e. my full name and e-mail address, by SVANTEK SP. Z O.O. with its registered office in Warsaw at ul. Strzygłowska 81 for the purpose of receiving marketing information on the products and services offered by SVANTEK SP. Z O.O. via electronic means of communication, in particular via e-mail, in accordance with the provisions of Article 10 sec. 1 and 2 of the Act on providing services by electronic means.

    I hereby consent to the processing of my personal data, i.e. my full name and phone number, by SVANTEK SP. Z O.O. with its registered office in Warsaw at ul. Strzygłowska 81 for the purpose of marketing activities with the use of telecommunications terminal equipment and automatic calling machines within the meaning of the Telecommunications Act.

    I hereby consent to receiving from SVANTEK SP. Z O.O. with its registered office in Warsaw at ul. Strzygłowska 81, via electronic means to the e-mail address I have provided, the newsletter and marketing information on the products and services offered by SVANTEK SP. Z O.O., within the meaning of the Act on providing services by electronic means.


    I declare that I have been informed that my data may be transferred to entities that process personal data on behalf of the Administrator, in particular to distributors - such entities process data on the basis of an agreement with the Administrator and exclusively in accordance with its instructions. In such cases, the Administrator requires third parties to maintain the confidentiality and security of information and verifies that they provide appropriate measures to protect personal data.

    Some of the entities processing personal data on behalf of the Administrator are established outside the EEA. In connection with the transfer of your data outside the EEA, the Administrator verifies that these entities provide guarantees of a high level of personal data protection. These guarantees stem in particular from the obligation to apply the standard contractual clauses adopted by the Commission (EU). You have the right to request a copy of the standard contractual clauses by sending a request to the Controller.

    I declare that I have been informed on my right to withdraw my consent to the processing of my personal data at any time, to access the provided personal data, to rectify, erase, restrict processing and object to the processing of my data, as well as the right to lodge a complaint with the President of the of the Personal Data Protection Office in the event of an infringement of the provisions of GDPR.










      Products in the enquiry (1)

      Please select desired dates:

      I hereby consent to the processing of my personal data, i.e. my full name and e-mail address, by SVANTEK SP. Z O.O. with its registered office in Warsaw at ul. Strzygłowska 81 for the purpose of receiving marketing information on the products and services offered by SVANTEK SP. Z O.O. via electronic means of communication, in particular via e-mail, in accordance with the provisions of Article 10 sec. 1 and 2 of the Act on providing services by electronic means.

      I hereby consent to the processing of my personal data, i.e. my full name and phone number, by SVANTEK SP. Z O.O. with its registered office in Warsaw at ul. Strzygłowska 81 for the purpose of marketing activities with the use of telecommunications terminal equipment and automatic calling machines within the meaning of the Telecommunications Act.


      I declare that I have been informed that my data may be transferred to entities that process personal data on behalf of the Administrator, in particular to distributors - such entities process data on the basis of an agreement with the Administrator and exclusively in accordance with its instructions. In such cases, the Administrator requires third parties to maintain the confidentiality and security of information and verifies that they provide appropriate measures to protect personal data.

      Some of the entities processing personal data on behalf of the Administrator are established outside the EEA. In connection with the transfer of your data outside the EEA, the Administrator verifies that these entities provide guarantees of a high level of personal data protection. These guarantees stem in particular from the obligation to apply the standard contractual clauses adopted by the Commission (EU). You have the right to request a copy of the standard contractual clauses by sending a request to the Controller.

      I declare that I have been informed on my right to withdraw my consent to the processing of my personal data at any time, to access the provided personal data, to rectify, erase, restrict processing and object to the processing of my data, as well as the right to lodge a complaint with the President of the of the Personal Data Protection Office in the event of an infringement of the provisions of GDPR.

      ]

      Technical

      Specification

      SV 102A+ Class 1 Dual-Channel Noise Dosimeter

      Applications

      Sound measurements
      Occupational noise

      Hardware Features

      Number of channels 2
      Auto-calibration
      Keyboard lock
      Remote communication
      Bluetooth
      Communication Interfaces USB
      LED indicator
      Display
      Keyboard 4 buttons
      Memory 32 GB
      Battery type Two AA batteries (alkaline)
      Operating time > 16 h
      Operating temperature range from -10'C to 50'C
      Humidity range up to 90 % RH
      Weight 260g
      Size 95 x 83 x 33 mm
      Docking station required

      Sound measurements features

      Standards IEC 61252; ANSI S1.25-1991; Class 1: IEC 61672-1:2013, ISO 11904-1
      Microphone type ACO SV 7052E, prepolarised, 1/2” ; SV 25S, special microphone with probe for MIRE
      Preamplifier type SV 15
      Linear operating range to IEC 61672 45 dBA Leq÷ 141 dBA Peak
      Frequency range 20 Hz ÷ 20 kHz
      Weighting filters A, C and Z
      Time constants Slow, Fast, Impulse
      Statistics in octaves or third octaves
      Audio recording option
      Voice coments
      1/1 octave option
      1/3 octave option

      Files