The SV 971A Class 1 sound level meter is designed for use in measuring noise levels in occupational settings and for building acoustics measurements. Itย offers a linear measurement range of 27 to 140 dB in a single range, making it well-suited for a wide range of applications following British standards. The device is easy to use, thanks to dedicated mobile applications that support sound measurements as well as RT60 and STIPA. This makes it a versatile tool for professionals working in the field of acoustics or noise control.
A Class 1 Sound Level Meter is a type of sound measuring instrument that meets the performance criteria outlined in the BS EN 61672-1:2003 standard. These criteria include the linear operating range, frequency response, and temperature operating range of the device. In the context of British standards, a Class 1 sound level meter is considered to be suitable for use in measuring noise levels and ensuring compliance with relevant regulations and guidelines.
Class 1 Accuracy and Precision
Class 1 accuracy and precision by BS EN 61672-1:2003
Noise sources identification
Octave filters and audio recording
Connect to the mobile app
Make it easier to use the sound level meter
Compatibility with international standards
noise measurements following ISO, IEC, OSHA, MSHA, or ACGIH guidelines
Class 1 accuracy and precision by BS EN 61672-1:2003
Read more
Octave filters and audio recording
Read more
Make it easier to use the sound level meter
Read more
noise measurements following ISO, IEC, OSHA, MSHA, or ACGIH guidelines
Read more
The SV 971A sound level meter is designed to make noise measurement easier and faster. It is equipped with all frequency weightings, which allows it to measure sound pressure levels as well as peak sound pressure levels in workplace environments.
Noise at work
HSE guidelines
In the UK, occupational noise measurements are typically conducted according to the guidelines set forth by the Health and Safety Executive (HSE), which is the UK's national regulator for occupational health and safety. The HSE provides detailed guidance on how to conduct noise assessments in the workplace, including information on how to use sound level meters and other measurement tools, how to interpret measurement results, and what steps to take to protect workers from excessive levels of noise. Additionally, the HSE recommends that occupational noise measurements be conducted according to the standards established by the International Organization for Standardization (ISO), such as ISO 9612 and ISO 1999.
Read moreBuilding Acoustics
Sound insulation by BS EN ISO 16283
In the UK, sound insulation measurements are typically conducted according to the guidelines set forth by the British Standards Institution (BSI), which is the UK's national standards organization. The BSI provides detailed guidance on how to conduct sound insulation measurements, including information on how to use sound level meters and other measurement tools, how to interpret measurement results, and what steps to take to improve the sound insulation of buildings and other structures. Additionally, the BSI recommends that sound insulation measurements be conducted according to the standards established by the International Organization for Standardization (ISO), such as ISO 16283.
Read moreSTIPA Voice Level Meter
Speech transmission indexes for public address systems
The BSI recommends that STIPA measurements be conducted according to the standards established by the International Electrotechnical Commission (IEC) in its 60268 standard. This standard provides detailed instructions for conducting STIPA measurements and for interpreting the results. In organizing STIPA measurements and calculations, a dedicated mobile application can be used to support the use of a STIPA Voice Level Meter. This can make it easier to conduct the measurements and to interpret the results. The STIPA signal is typically reproduced by the loudspeakers in the public address system under study, but in some cases, dedicated loudspeakers may be used.
Read moreThe 971A Class 1 Sound Level Meter uses a microphone that offers a linear measurement range of 27 to 140 dB, making it well-suited for a wide range of applications.
|
Class 1 sound level meter sv 971a
The kit consists of an SV 971A Class 1 sound level meter with a detachable preamplifier (SV 18A), a high-quality, omni-directional ACO SV 7152 microphone that is compliant with the IEC 61094-4 standard. The list of accessories includes an SA 22 windscreen, a 32 GB microSD card, four AAA batteries, a USB cable, and a pendrive with the user manual. Each SV 971A comes with a factory calibration certificate and a 36-month warranty card. |
|
SVANPC++_BA - Building Acoustic Module License The optional PC software module provides a very powerful extension to the mobile application with the advanced calculations of reverberation time and sound insulation. |
|
SVANPC++EM - Environmental Module License The PC software module is designed for data post-processing from noise and vibration measurements. It provides all necessary functionalities for marking / removing / recalculation... |
|
SF 971A_P2 - options package to SV 971A: RT60 and STIPA Firmware options package to SV 971A: RT60 reverberation time and STIPA. Both functions are supported by a mobile application for measurement of sound insulation in accordance... |
See all accessories
Open list
List of accessories
|
SF 971A_20 - Speech transmission index (STIPA) option for SV 971A |
|
SF 971A_15 - License for Audio Recording to SV 971A |
|
SF 971A_5 - Reverberation time analysis (RT60) option for SV 971A |
|
SF 971A_1 - License of 1/1 octave analysis option for SV 971A |
|
SV_CA_SLM - Accredited calibration of the sound level meter according to EN 61672-3:2014 |
|
SV 33B - Class 1 Sound Calibrator: 114 dB @ 1 KHz |
|
SA 72 - Waterproof carrying case |
|
SUPERVISOR - PC Software |
|
SC 158 - USB-C to USB-A communication cable |
|
SC 91A/05 - Extension cable for SV 18A, 5 meters |
|
SA 22 - Windscreen for 1/2"" microphone (70 mm) |
|
SV 36 - Class 1 Sound Calibrator 94dB / 114dB @ 1kHz |
|
Building Acoustics PRO Application |
|
SF 971A_2 - License of 1/3 octave analysis for SV 971A |
|
SV_CA_AC1 - Acoustic calibrator calibration (single level) |
Class 1 sound level meter sv 971a
Applications
Hardware Features
Please select the file and language version