V I B R A T I O N M O N I T O R I N G
|
| Standards |
DIN 4150 |
| Meter mode |
RMS, VDV, MTVV or MAX, Peak, Peak-Peak
Simultaneous measurement in four-channels with independent set of filters and detector constants |
| Analyser (option) |
1/1 octave1 real-time analysis, 15 filters with centre frequencies from 1 Hz to 16 kHz (Type 1)
1/3 octave1 real-time analysis, 45 filters with centre frequencies from 0.8 Hz to 20 kHz (Type 1)
FFT1 real-time analysis up to 1920 lines with Hanning, Kaiser-Bessel or Flat Top window |
| Filters |
KB (DIN 4150), HP1, HP3, HP10, Vel1, Vel3, Vel10, VelMF, Dil1, Dil3, Dil10, Wd , Wk , Wc , Wj , Wm, Wb , Wg (ISO 2631), Wh (ISO 5439) |
| RMS & RMQ Detectors |
Digital True RMS & RMQ detectors with Peak detection, resolution 0.1 dB
Time-constants: from 100 ms to 10 s |
| Accelerometer Set (option) |
SV 207: Dytran 3233A accelerometer (triaxial, 1 V/g sensitivity) in robust metal hermetic box with levelling system
|
| Measurement Range |
1 mm/s2 RMS ÷ 50 m/s2 Peak with HP1 filter and accelerometer sensitivity equal to 1 V/g |
| Frequency Range |
0.4 Hz ÷ 3000 Hz with SV 207 accelerometer |
| |
| S O U N D M O N I T O R I N G |
| Standards |
Type 1: IEC 61672-1:2002 |
| Meter mode |
SPL, Leq, SEL, Lden, Ltm3, Ltm5, Statistics - Ln (L1-L99), LMax, LMin, LPeak
Simultaneous measurement in three profiles per channel with independent set of filters and detectors
|
| Analyser (option) |
1/1 octave1 real-time analysis, 15 filters with centre frequencies from 1 Hz to 16 kHz (Type 1)
1/3 octave1 real-time analysis, 45 filters with centre frequencies from 0.8 Hz to 20 kHz (Type 1)
FFT1 real-time analysis up to 1920 lines with Hanning, Kaiser-Bessel or Flat Top window |
| Weighting Filters |
Standard: A, C, Z and special B and G |
| RMS Detector |
Digital True RMS detector with Peak detection, resolution 0.1 dB
Time-constants: Slow, Fast, Impulse |
| Microphone Set (option) |
SV 208: SV 22 prepolarised 1/2” condenser microphone (sensitivity 50 mV/Pa), SV 12L preamplifier, SA 203 outdoor protection kit for airport and community noise monitoring |
| Measurement Range |
22 dBA RMS ÷ 140 dBA Peak (with 5 dB margin from noise level and SV 22 microphone) |
| Internal Noise Level |
Less than 17 dBA RMS |
| Frequency Range |
10 Hz ÷ 20 kHz with SV 22 microphone |
| |
| M E T E O D A T A S V 2 0 5 (option) |
| Temperature Range |
-40 oC ÷ 124 oC (±0.3 oC) |
| Ambient Pressure Range |
150 hPa ÷ 1150 hPa (±5 hPa) |
| Humidity |
0 % ÷ 100 % (±2 %) |
| Wind Speed |
0 m/s ÷ 60 m/s (±2 %)
|
| Wind Directions |
0o ÷ 359o (±3o) |
| |
| B A S I C D A T A S V 2 1 3 |
| Input |
IEPE type, channels 1, 2, 3, 4 (all waterproof connectors) |
| Dynamic Range |
100 dB, 4 x 20 bits A/D converters |
| Frequency Range |
0.5 Hz ÷ 20 kHz, sampling rate 48 kHz |
| Data Logger |
Time-history logging to internal memory or external USB Memory Stick
Time-domain signal recording on USB Memory Stick (option) |
| Memory |
32 MB non-volatile flash type, external USB Memory Stick |
| Interfaces |
USB 1.1 Client, USB 1.1 Host, RS 232 (with SV 55 option) |
| Remote Communication |
GPRS modem (option)
LAN & WLAN module (option) |
| Power supply |
|
DC power supply
|
24 V (waterproof connector)
|
|
Mains power supply
|
100 V ÷ 240 V (waterproof connector)
|
|
Internal battery
|
33 Ah (12 V)
|
|
| Environmental Conditions |
|
Temperature
|
from -10oC to 50oC
|
|
| Dimensions |
475 x 385 x 240 mm (without antenna) |
| Weight |
Approx. 22 kg including batteries |
| |